Email: CreateEmail: SendExport ImageExport TextHTTP Client CreateHTTP Client RequestModbus Client: InitialiseModbus Client ReadModbus Client WriteMQTT Client: InitialiseMQTT Client PublishMS Teams Workflow: CreateMS Teams Workflow: SendPATLITE LA6POE: InitialisePATLITE LA6POE WritePrimus TL: InitialisePrimus TL: WriteTCP/IP Client: SetupTCP/IP Client: SendTelegram Bot: CreateTelegram Bot: SendBasler CameraClient Media InputIP Camera Multi InputIP Camera InputServer Media InputWebcam
Widgets

Miscellaneous

Nomenclature
Troubleshooting
Notice and DisclaimerEULA
NodesIo

Primus TL: Initialise

Slot Usage: 2
Child Nodes
Primus TL: Write

Overview

Primus TL: Initialise configures Modbus connectivity to a Primus TL tower light device over TCP/IP or RTU.

Set this once, then control lights and buzzer with Primus TL: Write.

Input

Type

string required

Modbus connection type:

  • TCP — TCP/IP
  • RTU — serial RTU

Default: TCP

Device ID

integer required

Modbus slave / device ID of the Primus TL unit.

Range: 0 to 1024
Default: 1

Host

string

Required when Type is TCP.

Hostname, IPv4, or IPv6 address of the Modbus server (slave).

TCP/IP Server port

integer

Required when Type is TCP.

TCP port for Modbus communication.

Range: 0 to 65535
Default: 512

RTU port

integer

Required when Type is RTU.

RTU client communication port.

Range: 0 to 1024
Default: 1

Baud rate

string

Required when Type is RTU.

Values: 4800, 9600, 19200, 38400
Default: 9600

Parity

string

Required when Type is RTU.

Values:

  • NONE
  • EVEN
  • ODD

Default: NONE

Output

This node does not provide custom output fields.